| Summary: | VPE wird falsch ermittelt | ||
|---|---|---|---|
| Product: | [SCX/Suite] VMI | Reporter: | Hopmann, Peter <Peter.Hopmann> |
| Component: | IF-Material | Assignee: | Hopmann, Peter <Peter.Hopmann> |
| Status: | VERIFIED FIXED | QA Contact: | Tilli, Benedikt <Benedikt.Tilli> |
| Severity: | normal | ||
| Priority: | P5 | ||
| Version: | 7.20 | ||
| Hardware: | All | ||
| OS: | All | ||
| Whiteboard: | |||
| Kundennummer: | Bestellnummer: | ||
| PV Übergabe: | --- | Phase Roadmap: | --- |
| Erledigt mit: | Indus | SAP Release: | --- |
| Transport: | M17K900186 | CRM-ID/Ticket: | |
| Bug Depends on: | 5320 | ||
| Bug Blocks: | |||
|
Description
Hopmann, Peter
2015-10-13 01:18:19 CEST
/GIB/DCV_SC_MATERIAL_DATA_S erweitern:
VPMNG_13_3 1 Type QUAN 13 3, Bezug MARA-MEINS
METHOD get_ekinfo_conversion_factor.
*#5230
IF ms_eina IS INITIAL.
read_ekinfo( ).
ENDIF.
IF ms_eina-umrez <> 0.
***5397 ef_factor = ms_eina-umren / ms_eina-umrez.
ef_factor = ms_eina-umrez / ms_eina-umren. "5397
ELSE.
ef_factor = 1.
ENDIF.
ENDMETHOD.
/GIB/DCVT012W_S ändern (eingebauter Typ):
VPMNG 1 Type QUAN 13 3 Verpackungsmenge
/GIB/CL_DCV_SC_MATERIAL->GET_EXPORT_DATA
...
MOVE-CORRESPONDING ms_data TO ls_transfer.
ls_transfer-vpmng = ms_data-vpmng_13_3. "5397